CHQLZ - MOLECULAR SIEVE 4A (INDICATING)
- MSDS: CHQLZ
- Manufacturer: MULTIFORM DESICCANTS INC
- Product Name: MOLECULAR SIEVE 4A (INDICATING)
- National Stock Number: 6850-01-140-5446
Product Identification
Product ID:MOLECULAR SIEVE 4A (INDICATING)
MSDS Date:10/21/1997
FSC:6850
NIIN:01-140-5446
MSDS Number: CHQLZ
Responsible Party
BUFFALO, NY 14213-2101
US
Emergency Phone: 716-883-8900
Info Phone: 716-883-8900
Cage: 22627
Contractor
Telephone: 716-824-8900
Cage: 22627
Ingredients
SODIUM OXIDE
CAS: 1313-59-3
Fraction By Weight: <30%
MAGNESIUM OXIDE
CAS: 1309-48-4
RTECS: OM3850000
Fraction By Weight: <5%
OSHA PEL 15 MG/M3 PARTICULATE
ACGIH TLV: 10 MG/M3;TDUST; 9293
ALPHA-ALUMINA (ALUMINUM OXIDE) (EPA LISTS ONLY FIBROUS
CAS: 1344-28-1
RTECS: BD1200000
Fraction By Weight: <30.0%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
SILICA GEL
CAS: 112945-52-5
RTECS: VV7310000
Fraction By Weight: <50%
OSHA PEL 6 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
COBALT CHLORIDE
CAS: 7646-79-9
RTECS: GF9800000
Fraction By Weight: <1%
OSHA PEL 0.05 MG CO/M3
ACGIH TLV: 0.05 MG CO/M3
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MAY CAUSE EYE, SKIN & MUCOUS
MEMBRANE IRRITATION. CHRONIC: PROLONGED INHALATION MAY CAUSE LUNG
DAMAGE.
Explanation of Carcinogenicity:THIS PRODUCT AND ITS COMPONENTS ARE NOT
LISTED ON THE IARC, NTP OR OSHA CARCINOGENS LISTS.
Effects of Overexposure:EYE, SKIN AND MUCOUS MEMBRANE IRRITATION.
Medical Cond Aggravated by Exposure:BREATHING OF DUST MAY AGGRAVATE
ASTHMATICS AND INFLAMMATORY OF FIBROTIC PULMONARY DISEASES.
First Aid
First Aid:EYES: FLUSH EYES WITH WATER FOR 15 MINUTES AND CONTACT
PHYSICIAN. SKIN: WASH AFFECTED AREA WITH SOAP AND WATER.
INHALATION: REMOVE TO FRESH AIR AND GET MEDICAL ASSISTANCE IF
NECESSARY. INGESTION: IN L ARGE QUANTITIES, DRINK (2) GLASSES OF
WATER. CONTACT PHYSICIAN FOR PERMISSION TO INDUCE VOMITING. THIS
PRODUCT GETS HOT AS IT ABSORBS WATER. BURNS TO MOIST BODY TISSUE
CAN RESULT IF CONTACT IS LONG.
Fire Fighting
Flash Point:DOES NOT BURN
Extinguishing Media:USE APPROPIATE MEDIA FOR SURROUNDING FIRE.
Fire Fighting Procedures:USED MATERIAL MAY CONTAIN PRODUCTS OF A
HAZARDOUS NATURE. THE USER MUST IDENTIFY HAZARDS & INFORM THE
FIREFIGHTERS OF THESE HAZARDS.
Unusual Fire/Explosion Hazard:WHEN EXPOSED TO WATER, THEY CAN GET QUITE
HOT. WHEN FIRST WETTED THEY CAN HEAT TO THE BOILING POINT OF WATER.
FLOODING WITH WATER WILL REDUCE TEMPERATURE LIMITS
Accidental Release
Spill Release Procedures:SWEEP THE SPILL AREA. COLLECT AND PLACE THE
SPILLED MATERIAL IN WASTE DISPOSAL CONTAINER. AVOID RAISING DUST.
Neutralizing Agent:NONE REQUIRED
Handling
Handling and Storage Precautions:AVOID BREATHING DUST. USE WITH
ADEQUATE VENTILATION. WASH AFTER HANDLING.
Other Precautions:USE GOOD PERSONAL HYGIENE.
Exposure Controls
Respiratory Protection:USE NIOSH APPROVED RESPIRATOR WHEN PEL MIGHT BE
EXCEEDED.
Protective Gloves:RECOMMENDED
Eye Protection:SAFETY GOGGLES WITH SIDE SHIELDS
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:AVOID RAISING DUST. AVOID CONTACT WIYH SKIN,
EYE AND CLOTHING.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:V7
Spec Gravity:2.1
Appearance and Odor:PRODUCT MAY APPEAR AS A BEAD, PELLET, MESH CAKE, OR
POWDER. ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
SUDDEN CONTACT WITH HIGH CONCENTRATIONS OF CHEMICALS HAVING HIGH HEATS
OF ADSORPTIONS.
Stability Condition to Avoid:MOISTURE (WATER) CAN CAUSE RISE IN
TEMPERATURE, CONTACT WITH SKIN MIGHT REULT IN BURNS.
Hazardous Decomposition Products:DOES NOT READILY DECOMPOSE. ABSORBED
MATERIAL SUCH AS HYDROCARBONS WILL BE MORE EASILY GIVEN OFF.
Disposal
Waste Disposal Methods:DISCARD ANY PRODUCT, RESIDUE, DISPOSABLE
CONTAINER OR LINER IN AN ENVIRONMENTALLY ACCEPTABLE MANNER IN FULL
COMPLIANCE WITH FEDERAL, STATE, LOCAL LAWS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.